The Midrand Plumbers Request a call-out

Geyser Repair
in Midrand

Geyser repair in Midrand starts with a test, not a new part. Element, thermostat, valves and wiring are checked in turn until the fault has a name, and you get the price in writing before anything is replaced, on an invoice your insurer or body corporate can use.

Request a call-out
Diagram of a geyser in a roof space installed to SANS 10254: element and thermostat, pressure control valve on the cold supply, vacuum breakers on hot and cold, temperature and pressure relief valve, drip tray drained outside and an electrical isolator. Roof space Ceiling to outside Cold supply to outside 1 2 3 4 5 6
Fig. 1A geyser in a roof space, installed to SANS 10254, and the parts that fail.
  1. 1Element and thermostat
  2. 2Pressure control valve
  3. 3Vacuum breakers, hot and cold
  4. 4Temperature and pressure relief valve
  5. 5Drip tray, drained to outside
  6. 6Electrical isolator

What gets tested, and what it usually means

Each symptom points to a short list of parts. The test decides which one it is.

SymptomUsuallyThe test
No hot water, power onElement or thermostatElement resistance, then the thermostat's cut-out
Trips the earth leakageElement shorting to earthInsulation test on the element
Overflow pipe dripping all dayRelief valve or pressure control valvePressure at the valve against its rating
Water through the ceilingTray, fittings or the tank itselfTray, connections and tank checked from the roof
Lukewarm water onlyThermostat setting, scaled element or a faulty mixerThermostat and element checked, mixers isolated
Banging when taps closePressure, or a loose pipe in the roofGauge reading and pipe brackets checked

In a complex, the geyser is yours even when the roof is not

If your home is a unit in a sectional title complex, the geyser probably sits in a shared roof. The rules on who pays are clearer than most owners expect.

In a sectional title complex, the roof space above your unit is usually common property. That makes it easy to assume that a geyser bursting up there belongs to the body corporate. The rules say otherwise, and knowing them before the call-out saves a week of emails.

Prescribed Management Rule 31 deals with water heaters directly. Even where a geyser forms part of the common property and is insured under the body corporate's policy, the owner of the section it serves must maintain, repair and replace it; where one geyser serves more than one unit, those owners share the cost.1 A geyser that serves only your unit is treated as part of your section.2

Two-storey townhouses and carports in a Gauteng complex under a cloudy sky
In a complex, the roof space is usually common property. The geyser in it is not.

The pipes follow a different rule. Section 3(1)(r) of the Sectional Titles Schemes Management Act puts the body corporate in charge of pipes that serve more than one section or the common property.3 So the hot pipe from your geyser to your bathroom is yours, while a cold feed that also supplies the unit next door is the scheme's. A leak where the two meet is where most of the arguments start, and a photo of exactly where the water comes from settles more of them than any letter.

The money usually runs through the scheme's insurance. The building policy normally carries the geyser claim, often with an excess the owner pays, and some schemes leave geysers out altogether.2 Insurers expect the installation to meet SANS 10254, which means a drip tray drained to the outside, vacuum breakers, a pressure control valve and a relief valve.4 A missing tray is one of the first things an assessor notices.

Before anyone climbs into the roof: tell the managing agent, ask whether geysers are on the scheme's policy, and have the invoice made out the way the insurer wants it. Every geyser job here is itemised so it can go straight into that claim.

How a geyser call-out runs

Electric, solar-assisted or gas, the order is the same: make it safe, find the part, price it, then repair.

  1. Power off, water off

    The isolator is switched off and the cold supply closed before any cover comes off.

  2. Test part by part

    Element resistance and insulation, the thermostat's cut-out, then the valves under pressure.

  3. Price the part

    The part, the labour and the reason, in writing. If the tank has failed, the route out of the roof is checked before the old geyser moves.

  4. Repair and refill

    The geyser is refilled with a hot tap open, so the air is out before the element is powered.

  5. Check and paper

    Temperature, valves and tray drain are checked, and the invoice is itemised for the insurer or the agent.

How a geyser repair is priced

No figure until the fault is known, but no surprises about how the figure is built.

ItemHow it is handled
Call-out feeStated on the phone before the visit. It covers getting there and the testing.
The partNamed on the written price, with its own line and price on the invoice.
LabourShown separately from the parts, so you can see what each costs.
AccessA low roof, a crawl space or a geyser that cannot leave the way it came in can change the price. You hear that before work starts.
After hoursAny after-hours rate is stated on the call, not discovered on the invoice.
Ceiling damageCeiling boards and paint after a burst are separate work, normally handled through the insurance claim.

Geyser questions, cost first

Including the two that cause most of the confusion: who pays in a complex, and when a geyser should be replaced.

What does a geyser repair cost in Midrand?

It depends on which part has failed, and that is only known after the test. A thermostat or an element is a modest part; a burst tank means a replacement, which is a different order of cost. You hear the call-out fee before the visit, and after the test you get a written price for the specific part before anything is replaced. If the geyser needs replacing, the price says so and says why.

Repair or replace: how is that decided?

By what failed. Elements, thermostats and valves are parts, and replacing the one that failed is the normal fix. A leak from the tank itself, through corrosion or a split seam, cannot be repaired, and that is the point at which replacement is quoted. Age alone is not a reason: a sound tank with a failed element gets a new element.

My geyser is in the roof of a complex unit. Who pays?

Usually you, through the scheme's insurance. Management rule 31 makes the owner responsible for the water heater serving their section, even where it sits on common property1. The body corporate's building policy normally carries the claim, often with an excess for the owner, and some schemes exclude geysers2. Ask the managing agent before work starts.

Will you deal with my insurer?

You get what the insurer asks for: an itemised invoice, photos of the failed part and of the installation, and a short note of the cause. The claim itself stays between you, the managing agent if there is one, and the insurer, so the paperwork is written to be forwarded as it is.

Why does the pipe on my outside wall keep dripping?

That pipe is usually the overflow from the temperature and pressure relief valve or from the pressure control valve. A steady drip means one of them is releasing: the valve may be worn, or the pressure or temperature it sees is higher than it is set for. A gauge reading tells which, and the fix is then the valve or the pressure, not a new geyser.

The geyser trips the electricity. Is that the element?

Most often, yes. An element whose sheath has cracked lets water reach the heating wire and trips the earth leakage. An insulation test confirms it in minutes. A thermostat fault or damaged wiring at the isolator can do the same, which is why the test comes before the part.

Can a geyser be installed without a drip tray?

Not to the standard. SANS 10254 calls for a drip tray with its overflow taken to the outside of the building4, and an assessor looks for it after a burst. If your geyser has no tray, or a tray that drains into the ceiling, it is worth putting right during any repair.

Is a gas or solar geyser an option instead?

Either can be, and each changes the job. A gas geyser needs a cylinder position that meets the distance rules, covered on the gas installation page. A solar geyser needs a roof you are allowed to use and a collector chosen with hail in mind, covered on the solar geyser page.

Request a call-out

Say whether it is electric, gas or solar, whether water is coming through the ceiling, and whether you are in a complex. We phone back with the fee and a time.

Call-out requestFields marked * are needed

Your details are used only to answer this request. See the privacy notice.

Service area

Geyser call-outs across Midrand, from Vorna Valley and Halfway Gardens to Kyalami, Carlswald and Rabie Ridge.

BookingRequest a call-out

AreaMidrand, City of Johannesburg

Suburbs covered

  • Barbeque Downs
  • Blue Hills
  • Carlswald
  • Country View
  • Crowthorne
  • Ebony Park
  • Glen Austin
  • Halfway Gardens
  • Halfway House
  • Ivory Park
  • Kaalfontein
  • Kyalami
  • Noordwyk
  • President Park
  • Rabie Ridge
  • Randjesfontein
  • Randjespark
  • Vorna Valley
  • Waterfall